Photoluminescent indicator for evacuation: how it works

Workplace safety

Photoluminescent indicator for evacuation: how it works

A photoluminescent indicator for evacuation shall accumulate light during the day and shall give it back in the form of a spark when the current is interrupted. Thus, exits, fire extinguishers and first aid points remain easy to find in the dark. See how it works and how you use it properly.

In short: the sign loads to light, shines in the dark, and its efficiency depends on environmental lighting, location and cleanliness.

Do you need help choosing?

Tell us what you need and we'll send you the offer on the same working day.

Photoluminescent signals provide orientation immediately after power outage, without cables and without batteries. For good results, ensure sufficient light for charging, mount the signs at each direction change and periodically test the route in the dark, including after any rearrangement. Choose each photoluminescent indicator for evacuation from exit to assembly place, from category Photoluminescent safety indicators.

A photoluminescent indicator for evacuation remains visible and when light suddenly disappears. For example, at a power failure in a windowless warehouse, the halls become completely dark in seconds. In this case, the usual signs no longer help, while the photoluminescent surface begins to shine. Therefore, people continue to see the way out, the extinguisher or the first aid point.

How a photoluminescent indicator works for evacuation

The photoluminescent material contains pigments that absorb the energy of the light in the chamber. Then, after the light is out, the pigments gradually release this energy in the form of a green glow. In other words, the sign works as a battery of light, without cables and without power supply. However, the brightness is falling in time, so the sign helps especially in the early moments of evacuation. Therefore, a photoluminescent indicator for evacuation completes the safety systems, does not replace them.

Why the light in the room matters

The sign needs light to charge. Therefore, in a always dark hallway, the material does not accumulate enough energy. For example, a house with lamps on the motion sensor can offer too little light for charging. Instead, the permanently illuminated hallways during the program load the surface well. Thus, before mounting, check that each photoluminescent indicator for evacuation receives sufficient light during the day.

What messages do you find with photoluminescent signs

Category photoluminescent safety indicators comprises 14 models, for exits, equipment and assembly places. Below we group them after the role they have in evacuation.

Outputs and directions of movement

Range includes the sign Exit, but also variants with direction: left, right, down, forward, left up or left down. For example, Output before Fits in the long, straight hallways. Then, Exit left down shows the descent to the left, like at the beginning of a staircase. Thus, each photoluminescent indicator for evacuation from the path indicates the real direction, even in the dark. At the same time, it uses the same family of signs throughout the route, so that people do not compare different styles in times of stress.

Equipment: switch off, telephone, first aid

In addition to exits, people need to quickly find intervention equipment. For example, the sign Shut-off Mark the position of the extinguisher on the wall. At the same time, the plate Telephone for rescue cases Shows where the emergency phone is. The range also includes two variants for the first aid point. In other words, thanks to a photoluminescent indicator for evacuation, the employee finds not only the door, but also the means of intervention.

Place of assembly

The evacuation ends at the assembly point, where the team checks if anyone is missing. Therefore, the sign Place of assembly in case of emergency It helps especially in the night shift. Therefore, the sign from the outside remains visible and when the lighting of the court does not work. In addition, the sign helps intervention teams quickly identify the area where people are evacuated.

Where you mount a photoluminescent indicator for evacuation

  • Above the escape doors and the final door to the outside.
  • At each directional change, so that the next sign appears from the previous one.
  • Near the extinguishers, internal hydrants and first aid points.
  • On the stairs, especially where there are no windows.

Also think about the smoke, which goes up to the ceiling and can cover a photoluminescent indicator for evacuation mounted up. For this reason, some evacuation plans also provide signs at the level below, close to the floor. However, the exact height and the number of marks shall determine the designator, according to the requirements applicable to the building. For official information on fire prevention, see the website IGSU.

Photoluminescent or securely illuminated?

The two solutions are not excluded, but work together. On the other hand, safety lighting needs power supply and battery verification. Instead, a photoluminescent indicator for evacuation does not consume energy and does not depend on cables. Thus, in many buildings, the project combines safety lighting bodies with photoluminescent signs on the track. However, the final decision is the responsibility of the designer and takes into account the requirements applicable to each building. For classic green signs, see also category First aid and rescue indicators.

How to test a photoluminescent indicator

A simple test shows you if the signs do their job. First, leave the lights on during the usual program. Then, at night, turn off all the lights on the path and walk the way out. In this case, you immediately notice the signs that shine weak or that are missing from the field of vision. Thus, correct the position of a photoluminescent indicator for evacuation before a real situation.

Regular maintenance and verification

  • Wipe the dust with a wet wash, no solvents, because dirt reduces the load.
  • Check if the new shelves or decorations don't shade the sign.
  • Replace scratched, bleached or discoloured plates.
  • Repeat the test in the dark after each rearrangement.

In addition, note in the internal register the status of each photoluminescent indicator for evacuation, to track the evolution over time.

Frequently Asked Questions about Photoluminescent Indicators

How long does a photoluminescent indicator shine?

The duration depends on the material, the intensity of the light and the time of loading. However, the brightness is gradually decreasing, so consult the manufacturer's data before planning the route.

Does he need electricity?

No, the sign only loads from the environmental light. Thus, a photoluminescent indicator for evacuation remains functional and at a full current.

Can I mount the photoluminescent signs outside?

Yes, for example, at the assembly site, but check for sufficient light for loading. Finally, a well-maintained photoluminescent evacuation indicator remains visible at night.

View all models in category photoluminescent safety indicators and complete the escape route with visible signs in the dark. If you don't know which photoluminescent indicator for evacuation matches each point, Protrafic.ro helps you choose.

Recommended products

Recent articles

All articles

Cookie settings

Choose which categories you accept. Strictly necessary cookies are always active; the others start only with your consent and you can change them at any time. Cookie policy

They make the site work: shopping cart, favourites, customer account sign-in, form security and remembering your cookie choice. They cannot be disabled.

What we store (5)
  • erp-consent · This site · Stores your cookie choice. Duration: 365 days.
  • erpShop.cart · This site · Products in your shopping cart. Duration: until the cart is emptied.
  • erpShop.fav · This site · Products you saved to favourites. Duration: until you delete them.
  • __Host-*_sess · This site · Keeps you signed in to your customer account. Duration: session (12 hours) or 30 days with “Remember me”.
  • __Host-*_csrf · This site · Security: protects account forms against forged requests. Duration: session.

Remembers recently viewed products so you can find them easily. The data stays only in your browser.

What we store (1)
  • erpShop.seen · This site · Recently viewed products. Duration: until you delete them.

Shows us which pages are visited and how the site is used, so we can improve it (Google Analytics).

What we store (2)
  • _ga · Google Ireland Ltd. (Google Analytics) (third party) · Distinguishes visitors for visit statistics. Duration: 2 years.
  • _ga_4009D1RE45 · Google Ireland Ltd. (Google Analytics) (third party) · Keeps the state of the visit session. Duration: 2 years.

Video clips played directly on YouTube (Google). When playing, YouTube can store data in the browser.

What we store (1)
  • YSC, VISITOR_INFO1_LIVE, yt-remote-* · Google Ireland Ltd. (YouTube) (third party) · Video playback and YouTube statistics; only after you start a video. Duration: session – 6 months.
Third-party providers (2)